ÇѱÛÁ¦¸ñ(Korean Title) ºÎ½º¹Ù Á¢ÃË »óÅ ¹× ¿Âµµ °¨Áö ½Ã½ºÅÛ ¼³°è ¹× ±¸Çö
¿µ¹®Á¦¸ñ(English Title) A Design and Implementation of Busbar Joint and Temperature Measurement System
ÀúÀÚ(Author) ÀÌ¿µµ¿   Á¤¼ºÇР  Young-dong Lee   Sung-Hak Jeong  
¿ø¹®¼ö·Ïó(Citation) VOL 21 NO. 02 PP. 0379 ~ 0385 (2017. 02)
Çѱ۳»¿ë
(Korean Abstract)
ÀϹÝÀûÀ¸·Î ¹èÀü¹Ý, ºÐÀü¹Ý, Àüµ¿±âÁ¦¾î¹Ý(Motor Control Center; MCC)Àº Áý´Ü°ÅÁÖÁö¿ª, ºôµù, Çб³, °øÀå, Ç׸¸, °øÇ×, »óÇϼö ó¸®Àå, º¯Àü¼Ò, Áß°ø¾÷ Ç÷£Æ® µîÀÇ ±¤¹üÀ§ÇÑ Àü·Â ¼ö¿ë°¡¿¡ ¼³Ä¡µÇ¾î Ư°í¾ÐÀÇ Àü·ÂÀ» ÇØ´ç ¼³ºñµé¿¡ ¿ä±¸µÇ´Â Àü¾ÐÀ¸·Î º¯È¯ÇÏ¿© °ø±ÞÇϴµ¥ »ç¿ëµÈ´Ù. ÀÌ¿Í °°Àº ¹èÀü¹Ý, ºÐÀü¹Ý, MCC¿¡ Æ÷ÇԵǴ Àü±â¼³ºñÀÇ »ç°í´Â ºÎ½º¹Ù Á¢Ã˺ÎÀÇ ¿­È­¿¡ ÀÇÇÑ »ç°í, ºÎ½º¹ÙÀÇ Á¢Á¡ ¹× ¿¬°á ºÎÀ§¿¡¼­ÀÇ Á¢ÃË ºÒ·®¿¡ ÀÇÇÑ »ç°í, ºÎ½º¹Ù Á¢Ã˺ÎÀÇ °ú¿­Çö»ó¿¡ ÀÇÇÑ »ç°í·Î ±¸ºÐµÈ´Ù. º» ³í¹®¿¡¼­´Â ºÎ½º¹Ù Á¢Ã˺ÎÀÇ º¼Æ® ¹× ³ÊÆ®ÀÇ Ç®¸²»óÅÂ, Á¢Ã˺Π¿­È­ ÃøÁ¤ÀÌ °¡´ÉÇϸç, Á¤¹Ð °¡º¯ÀúÇ×À» ÀÌ¿ëÇÏ¿© ÀúÇ×°ªÀÇ º¯È­¿¡ µû¶ó º¼Æ® ü°á»óÅ °¨Áö ¹× ºñÁ¢ÃË½Ä Àû¿Ü¼± ¼¾¼­¸¦ »ç¿ëÇÏ¿© ºÎ½º¹Ù Á¢Ã˺Π¿Âµµ °¨Áö ½Ã½ºÅÛÀ» ¼³°èÇÏ°í ±¸ÇöÇÏ¿´´Ù. ºÎ½º¹Ù Á¢Ã˺Πü°á»óÅ °¨Áö¸¦ À§ÇÑ °¡º¯ÀúÇ×À» ÀÌ¿ëÇÑ ½ÇÇèÀ» ¼öÇàÇÑ °á°ú º¼Æ®¿Í ³ÊÆ®¸¦ ¿ÏÀüÈ÷ ü°á½ÃÅ°¸é °¡º¯ÀúÇ× °ªÀº °¨¼ÒÇÏ¿´À¸¸ç, ÃÖ´ë ¿ÀÂ÷¹üÀ§´Â 0.1mmÀÇ °á°ú¸¦ º¸¿´´Ù. ¶ÇÇÑ, ºÎ½º¹Ù Á¢ÃË ÀúÇ×°ª º¯È­¿¡ µû¶ó Á¢Ã˺Π¿Âµµ°¡ 27.3¡É¿¡¼­ 69.3¡É·Î »ó½ÂÇÏ´Â °á°ú¸¦ È®ÀÎÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact between busbar, deterioration of the contact resistance, over temperature of the busbars. In this paper, we designed and implemented the busbar joint and temperature measurement system, which can measure the joint resistance of busbar and loose connection between busbar using potentiometer and non-contact infrared sensor. The experimental results show that tightening the bolt and nut is fully engaged, resistance was decreased and maximum error range was 0.1mm. Also, the experimental result showed that the temperature at the contact area is increased from 27.3¡É to 69.3¡Éby the contact resistance.
Å°¿öµå(Keyword) ºÎ½º¹Ù   ¹èÀü¹Ý   ºÐÀü¹Ý   Àüµ¿±âÁ¦¾î¹Ý   ü°á»óÅ ¸ð´ÏÅ͸µ   Busbar   distribution board   panel board   motor control center   busbar joint monitoring  